DeviceNet Master
Bugs:
- PSDNM-481: Communication fails sometimes when production inhibit time is not zero (1,2,3..)
- PSDNM-483: When the I/O data is fragmented and slave has delay in poll response, the master poll request cause disruption in receiving of fragmented response from slave
Bugs:
- PSDNM-467: I/O Timeout should not depend on fragmented timeout.
- PSDNM-470: DeviceNet Master re-allocate the poll connection when remote service request sent
- PSDNM-475: Cifx slot number is resetted when the windows host application access cifx driver xChannel functions
- PSDNM-476: DeviceNet master trim variables (i.e class, instance, attribute) to 1 bytes when the slave has body format 0 without notice on remote service request
- PSDNM-477: Acyclic data appears as cyclic data
Bugs:
- PSDNM-459: DeviceNet Master can not communicate with maximal 63 slaves.
- PSDNM-460: Bitstrobe request dataload is different than the DPM
- PSDNM-461: 24V missing status is not updated when master is configured alone on the network.
- PSDNM-464: ulErrorCounter in SYCON.net diagnosis should not be clear when the error is gone
New Features:
- PSDNM-471: Support of object specific service code 0x4b and 0x4c
Bugs:
- PSDNM-455: Invalie use of TLR_BOOLEAN in API Header
- PSDNM-459: DeviceNet Master can not communicate with maximal 63 slaves.
- PSDNM-460: Bitstrobe request dataload is different than the DPM
- PSDNM-461: 24V missing status is not updated when master is configured alone on the network.
New Features:
- PSDNM-454: [NXO] Create a new NXO target for rcx V2.1
Bugs:
- PSDNM-459: DeviceNet Master can not communicate with maximal 63 slaves.
- PSDNM-460: Bitstrobe request dataload is different than the DPM
Bugs:
- PSDNM-387: Unneeded section in DeviceNet Master's Extended Diagnosis.
- PSDNM-396: Firmware can be configured with more than maximum number of cyclic input/output data stated in Protocol API.
- PSDNM-402: MNS led stays green without bus power
- PSDNM-404: LED stays green blinking after 24V removed
- PSDNM-410: Indication of CAN bus off error in DPM is cleared while actual error still exists
- PSDNM-419: Incorrect firmware name and version when master license is missing
- PSDNM-424: No communication error is reported, when there is no data exchange with one of the configured slaves.
- PSDNM-428: Stopping of the master device communication via the DTM's context menu counts as an error in the "General diagnosis".
- PSDNM-435: Incorrect firmware name and version when master license is missing
- PSDNM-437: Support of showing the diagnosis state of a slave.
- PSDNM-439: When downloaded with database with "controlled by application" the ulCommuncationError show TLR_E_APPLICATION_NOT_READY and RCX_COMM_COS_BUS_ON not set
- PSDNM-444: DeviceNet Master get active on bus even if controlled by application
- PSDNM-445: Resets of input from slave to zero about 2 second later als expected when the slave is disconnected from bus.
- PSDNM-446: DeviceNet Master do not show communication error in case of duplicate MAC ID
- PSDNM-447: Cannot set bit-strobed output of the master others than 0
- PSDNM-448: Register Application Request Count is not equal sum of negative und positive confirmations in Application Diagnosis
- PSDNM-455: Invalie use of TLR_BOOLEAN in API Header
New Features:
- PSDNM-454: [NXO] Create a new NXO target for rcx V2.1
Bugs:
- PSDNM-408: Not initialized data in RCX_GET_DEVICE_INFO_CNF_T after bus scan
- PSDNM-411: DEVNET_FAL_CMD_CLR_CONFIG_REQ does not accept correct packet length
- PSDNM-420: Master channel init does not work when commucation with the slave interrupt by database delete on slave
- PSDNM-422: Deconfiguration possible when 'CONFIG_LOCK' set.
- PSDNM-423: After watchdog timeout occurs TLR_E_WATCHDOG_TIMEOUT is not shown in Communication error
Changes:
- PSDNM-430: update to rcX v2.1.10.0 and v2.0.8.24
New Features:
- PSDNM-434: Provide DeviceNet Master Libraries with RCX v2.1.x support
Bugs:
- PSDNM-413: Quick connect does not work with 1791D-16B0
- PSDNM-415: DEVNET_FAL_CMD_REMOTE_SERVICE_REQ fails with timeout 0
Bugs:
- PSDNM-409: Channel Init does not clear packet configuration
- PSDNM-412: Cyclic and Change of State connection fails
Bugs:
- PSDNM-406: DeviceNet Master fails to connect to slaves with cyclic connection consumed size null
Bugs:
- PSDNM-397: DNM device does not send duplicate mac id check on bus when configured with packet as stand alone master (no slave configured)
- PSDNM-401: Master not functional after CAN Bus Off and bus power reset
- PSDNM-403: Wrong response on Firmware identify request
Bugs:
- PSDNM-398: DNM does not show led red when receive DUP MAC after first DUP MAC request sent during reset process of ID object
- PSDNM-399: DNM shows led green blinking when receive DUP MAC after first DUP MAC request sent during reset process of ID object